Deprecated: Optional parameter $depth declared before required parameter $output is implicitly treated as a required parameter in /mnt/web004/e1/45/57049045/htdocs/WordPress_01/wp-content/themes/appointment/functions/menu/appoinment_nav_walker.php on line 42 Warning: Cannot modify header information - headers already sent by (output started at /mnt/web004/e1/45/57049045/htdocs/WordPress_01/wp-content/themes/appointment/functions/menu/appoinment_nav_walker.php:42) in /mnt/web004/e1/45/57049045/htdocs/WordPress_01/wp-includes/rest-api/class-wp-rest-server.php on line 1713 Warning: Cannot modify header information - headers already sent by (output started at /mnt/web004/e1/45/57049045/htdocs/WordPress_01/wp-content/themes/appointment/functions/menu/appoinment_nav_walker.php:42) in /mnt/web004/e1/45/57049045/htdocs/WordPress_01/wp-includes/rest-api/class-wp-rest-server.php on line 1713 Warning: Cannot modify header information - headers already sent by (output started at /mnt/web004/e1/45/57049045/htdocs/WordPress_01/wp-content/themes/appointment/functions/menu/appoinment_nav_walker.php:42) in /mnt/web004/e1/45/57049045/htdocs/WordPress_01/wp-includes/rest-api/class-wp-rest-server.php on line 1713 Warning: Cannot modify header information - headers already sent by (output started at /mnt/web004/e1/45/57049045/htdocs/WordPress_01/wp-content/themes/appointment/functions/menu/appoinment_nav_walker.php:42) in /mnt/web004/e1/45/57049045/htdocs/WordPress_01/wp-includes/rest-api/class-wp-rest-server.php on line 1713 Warning: Cannot modify header information - headers already sent by (output started at /mnt/web004/e1/45/57049045/htdocs/WordPress_01/wp-content/themes/appointment/functions/menu/appoinment_nav_walker.php:42) in /mnt/web004/e1/45/57049045/htdocs/WordPress_01/wp-includes/rest-api/class-wp-rest-server.php on line 1713 Warning: Cannot modify header information - headers already sent by (output started at /mnt/web004/e1/45/57049045/htdocs/WordPress_01/wp-content/themes/appointment/functions/menu/appoinment_nav_walker.php:42) in /mnt/web004/e1/45/57049045/htdocs/WordPress_01/wp-includes/rest-api/class-wp-rest-server.php on line 1713 Warning: Cannot modify header information - headers already sent by (output started at /mnt/web004/e1/45/57049045/htdocs/WordPress_01/wp-content/themes/appointment/functions/menu/appoinment_nav_walker.php:42) in /mnt/web004/e1/45/57049045/htdocs/WordPress_01/wp-includes/rest-api/class-wp-rest-server.php on line 1713 Warning: Cannot modify header information - headers already sent by (output started at /mnt/web004/e1/45/57049045/htdocs/WordPress_01/wp-content/themes/appointment/functions/menu/appoinment_nav_walker.php:42) in /mnt/web004/e1/45/57049045/htdocs/WordPress_01/wp-includes/rest-api/class-wp-rest-server.php on line 1713 {"id":235,"date":"2018-10-24T22:23:59","date_gmt":"2018-10-24T22:23:59","guid":{"rendered":"http:\/\/hogtec.de\/?page_id=235"},"modified":"2020-09-29T09:01:16","modified_gmt":"2020-09-29T09:01:16","slug":"aktoren","status":"publish","type":"page","link":"https:\/\/hogtec.de\/aktoren\/","title":{"rendered":"Aktoren"},"content":{"rendered":"

S0-Aktor<\/h2>\n

Dieser Aktor im 3 TE -REG Geh\u00e4use simuliert einen S0-Z\u00e4hler. Somit k\u00f6nnen Ger\u00e4te welche keine direkte KNX Schnittstelle besitzen wie zum Beispiel Stromspeicher gesteuert werden, indem S0-Pulse ausgegeben werden.<\/p>\n

Auf der KNX Seite muss lediglich die aktuelle Leistung an den Aktor geschickt werden.<\/p>\n

Weiterhin verf\u00fcgt der Aktor \u00fcber ein Objekt zur prozentualen Drosselung der ausgegeben Leistung.<\/p>\n

 <\/p>\n

PWM-Aktor 2-Fach<\/h2>\n

\"KNX<\/p>\n

Dieser Aktor dient vorrangig dazu Heizungspumpen \u00fcber ein Pulsweitenmoduliertes Signal in der Leistung zu regeln.<\/p>\n

Er besitzt 2 unabh\u00e4ngige PWM Kan\u00e4le.<\/p>\n

Die Pumpen k\u00f6nnen Ein- und Ausgeschaltet, als auch stufenlos von 0-100% geregelt werden.<\/p>\n

PWM-Frequenz: 225Hz; 5V<\/p>\n

Anpassungen der Ausgangscharakteristik auf Wunsch \u00e4nderbar.<\/p>\n

N\u00e4heres in der Applikationsbeschreibung PWM-Aktor<\/a>.<\/p>\n

 <\/p>\n

Gateway zu zentralsolar PV- Wechselrichtern<\/h2>\n
Mit dem Gateway f\u00fcr ZSD Wechselrichter ist es m\u00f6glich folgende Daten auf den KNX Bus zu senden:<\/div>\n
 <\/div>\n
– aktuelle AC Leistung<\/div>\n
– aktuelle AC Spannung<\/div>\n
– aktuelle DC Leistung Tracker 1 und Tracker 2<\/div>\n
– aktuelle PV Spannung Tracker 1 und Tracker 2<\/div>\n
– Tagesertrag in kWh<\/div>\n
– Ertrag Total in kWh<\/div>\n
– Wechselrichtertemperatur<\/div>\n
– Fehlercodes<\/div>\n
 <\/div>\n
– Einstellen der maximalen Wechselrichterausgangsleistung bei Verwendung der 70% Regelung als Eispeiseregelung.<\/div>\n\t\t\t\t\t\t\t